Latest Products

  • Double Arm Sleeve Casing Winding Machine
  • Toroid Transformer Taping Machine
  • Dual Function Winding Taping Machine
  • Single Spindle Tube Winding Machine
  • Pressure-Applied Synchronous Tape Wrapping Machine
  • Fully Automatic Single-Axis, Single-Station PFC Magnetic Ring Winding Machine

Contact Us

GW-527 Component Parameter Test Instruments

GW-527 Component Parameter Test Instruments

lcr meter, GREWIN precision lcr meter , lcr meter datasheet, bench lcr meter, keysight lcr meter, GREWIN precision lcr meter, LCR meter, lcr meter datasheet, bench lcr meter Load Metrics (uses 18 credits), precision lcr meter, precision lcr meter specifications, precision lcr meter tariff code, GREWIN precision lcr meter, keysight e4980al precision lcr meter manual, GREWIN precision lcr meter , e4980a precision lcr meter, e4980al precision lcr meter, GREWIN precision lcr meter, agilent precision lcr meter manual, GREWIN precision lcr meter

Description

Features

■ 4.3-inch TFT LCD display

■ Selectable Chinese and English operation interfaces

■ Maximum test frequency of 1MHz, resolution of 10mHz

■ Transformer parameter test function

■ Maximum test speed: 13ms/time

■ Automatic level control (ALC) function for V and I

■ Test signal level monitor function for V and I

■ Included interior DC bias source

■ External DC bias source of large current

■ 10-point list sweep function

■ Selectable internal resistance of 30Ω, 50Ω and 100Ω

■ Built-in comparator:10-bin sorting and bin counter

■ Internal file storage and external USB-disk file storage

■ Test data can be saved to USB-disk directly

■ RS232C, USB, LAN, HANDLER, GPIB, DCI interface

 

Brief Introduction

■ GW-527 series is a new precision LCR meter with various functions and a higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. It is easy to operate with a 4.3-inch LCD screen as well as selectable

Chinese and English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

Specifications

 

 

Display

800×RGB×480

4.3-inch TFT LCD display

 

 

Frequency of test signal

GW-527A

20Hz—300kHz

GW-527C

20Hz—1MHz

Minimum resolution

 

10mHz, 4-digit frequency input

Accuracy

0.01%

 

 

 

 

 

 

 

 

 

 

AC

Level

Voltage range of test signal

 

5mV—2Vrms

Minimum resolution of voltage

 

100μV, 3-digit input

 

 

Accuracy

ALC ON

10% x set voltage + 2mV

ALC OFF

 

6% x set voltage + 2mV

Current range of test signal

 

100μA—20mA

Minimum resolution of current

 

1μA, 3-digit input

 

 

Accuracy

ALC ON

10% x set current + 20μA

ALC OFF

 

6% x set voltage + 20μA

 

 

DC

bias voltage source

Voltage

/Current range

 

0V— ±5V / 0mA—±50mA

Resolution

0.5mV / 5μA

Voltage accuracy

1% x set voltage + 5mV

 

ISO ON

Be used for the bias test of inductance and transformer

 

AC Source impedance

ISO ON

100Ω

ISO OFF

 

30Ω、50Ω、100Ω selectable

DCR source impedance

30Ω、50Ω、100Ω selectable

 

Test parameters of LCR

|Z|, |Y|, C, L, X, B, R, G, D, Q, θ,

DCR, Vdc-Idc

Parameter display of test page

One set of main/sub parameter, 10-point list sweep

 

 

Test parameters of transformer

DCR1(primary, 2-terminal), DCR2(secondary, 2-terminal), M (mutual inductance), N, 1/N,

Phase, Lk(leakage inductance),

C(primary, secondary capacitance),


Hot Tags: gw-527 component parameter test instruments, China, suppliers, manufacturers, factory, price, made in China


 

 

 

Basic accuracy

LCR test parameter

0.05%


N

0.1%


 

 

Calibration

Warm-up time ≥ 30 seconds;

Env ironment t emperat ure: 

23±5ºC;

Signal voltage: 0.3Vrms-1Vrms; Zeroing: After OPEN or SHORT; Length of test cable: 0 m

 

Measurement time

(≥10 kHz)

Fast: 13 ms / time Medium: 67 ms / time Slow:187 ms / time

Plus the refresh time of display character

 

 

 

 

 

 

Display range of LCR parameter

|Z|,R , X,DCR

0.00001Ω — 99.9999MΩ


|Y|,G,B

0.00001μs — 99.9999s


C

0.00001pF — 9.99999F


L

0.00001μH — 99.9999kH


D

0.00001 — 9.99999


Q

0.00001 — 99999.9


θ(DEG)

-179.999º — 179.999º


θ(RAD)

-3.14159 — 3.14159


Δ%

-999.999% — 999.999%

Equivalent circuit

Serial, Parallel

Range mode

Auto, Hold

Trigger mode

Internal, Manual, External, Bus

Average times

1-255

 

Calibration function

Open,

short calibration with full frequency or dot frequency,

Load

Math operation

Direct reading, ΔABS, Δ%

Delay time setup

0-999, minimum resolution: 100us

 

 

 

Comparator

10-bin sorting, BIN1-BIN9, NG, AUX


Bin counter


PASS/FAIL on front panel, LED indication

 

 

List sweep

·201 points list sweep

·Frequency, AC voltage/current, internal/external bias voltage/ current can be swept.

·Each sweep point can be sorted separately.

Internal nonvolatile memory

40 sets of LCRZ setting files

 

External USB memory

GIF files

LCRZ setting files

Test data can be stored via USB

memory directly.

 

 

 

Interface

I/O interface

HANDLER on rear panel

SCI

USB、RS232C

PCI

GPIB (optional)

NI

LAN

Memory interface

USB HOST (front panel)

General Specifications

Operating temperature and humidity

0℃-40℃, ≤ 90%RH

 

Power supply

Voltage

99V-121V,

198V-242V AC

Frequency

47Hz-63Hz

Consumption

Max. 80 VA

 

Dimension(W×H×D)

280 mm × 88 mm × 370 mm (with no sheath)

369 mm × 108 mm × 408 mm

(with sheath)

Weight

Approx. 5 kg

 

Standard Accessories

Three core power cord

GW-5010 Gold-plated short circuit board

GW-5011AS 4 terminal pair Kelvin test clip leads(only GW-527A)

GW-5011BS 4 terminal pair Kelvin test clip leads(only GW-527C)

GW-5024 Four-terminal test fixture 

GW-5019 Four-terminal test fixture




Send Inquiry

(0/10)

clearall