Latest Products

  • Double Arm Sleeve Casing Winding Machine
  • Toroid Transformer Taping Machine
  • Dual Function Winding Taping Machine
  • Single Spindle Tube Winding Machine
  • Pressure-Applied Synchronous Tape Wrapping Machine
  • Fully Automatic Single-Axis, Single-Station PFC Magnetic Ring Winding Machine

Contact Us

Small Magnetic Ring Transformer Tester video

Small Magnetic Ring Transformer Tester

Sensor’s type:Ф9.5 Ф6 Ф4
Winding’s shape:Inner diameter >Ф4mm outer diameter<120mm height<110mm
Winding measurement range:1~30000
Winding measurement accuracy:500~30000 circle ±0.3%
Winding basic measurement speed:1.5 measurements /second
Resistance measurement range:100uΩ-20kΩ
Resistance basic measurement speed:3 times /second

Description

NAME: Small Magnetic Ring Transformer Tester   (GW-2100R)

 

Sensor’s type

Ф9.5    Ф6     Ф4

Winding’s shape

Inner diameter >Ф4mm outer diameter<120mm height<110mm

Winding measurement range

1~30000

Winding measurement accuracy

500~30000 circle ±0.3%

Winding basic measurement speed

1.5 measurements /second

Resistance measurement range

100uΩ-20kΩ

Resistance basic measurement speed

3 times /second

Resistance measurement accuracy

0.2%

Range mode

Auto selection

Display mode

6-digit LED

Alarm selection

Short-circuit ,phase ,quiet

Dimensions (W*H*D)

335×320×290mm

Weight

Approx.6kg

Working temperature & humidity

0℃-40℃,≤90%RH

Power requirement

198-242VAC 47.5-52.5HZ

Power consumption

≤30VA


Working environment:

 

Temperature   0℃~40℃

Humidity    ≤90℅RH

Atmospheric pressure 86~104Pa

 

The range of turns testing:

1 ring~30000 ring

 

The range of winding turns

Measurement error

1~200

±0.1℅±1 Word

201~1000

±0.2℅±1 Word

1001~5000

±0.3℅±2 Word

Turns dimensions:

 

Inside diameter>4.5mm, Height<100mm,Outside diameter<100mm(The special sizes could be customs made)

 

Range:

Automatic selecting

Test current:

 

0.1mA、1mA、10mA、100 mA Four shifting gears automatic selecting

 

 The test range of resistance:

100uΩ~20kΩ

 

Resistance range

Measurement error

0.1Ω~0.9999Ω

±0.7℅±2 Word

1Ω~19.99Ω

±0.5℅±1 Word

20Ω~19.99KΩ

±0.3℅±1 Word

 

 


Hot Tags: small magnetic ring transformer tester, China, suppliers, manufacturers, factory, price, made in China

Send Inquiry

(0/10)

clearall